BS 8573 0.6/1kv CU/XLPE/LSZH Unarmored Cable

BS 8573 XLPE insulated and LSZH sheathed cables are used for fixed installation. They are suitable for building wiring, but not for burial in the ground.

    product detail

    Application:

      BS 8573 XLPE insulated and LSZH sheathed cables are typically utilized for fixed installation applications. These cables are well-suited for building wiring, particularly in settings where smoke and fume emissions may pose a potential risk to life. However, they are not intended for burial in the ground, either directly or in ducts.

     

    Standard
    Basic design to BS 8573:2012

    Voltage Rating
    600/1000V

    Construction:

    Conductor: Annealed copper conductor, strand according to BS EN 60228 class 2.

    Insulation: XLPE

    outer Sheath: Thermoplastic LSZH

    Minimum bending radius:

    • Circular copper conductors(up to 25mm²): 4 x Overall Diameter

    • Circular copper conductors(above 25mm²): 6 x Overall Diameter

    • Shaped copper conductors: 8 x Overall Diameter

     

    Parameters of BS 8573 Cable

    Conductor  Nominal Insulation Thickness Nominal Inner Covering Nominal Sheath Thickness Conductor  Nominal Insulation Thickness Nominal Inner Covering Nominal Sheath Thickness
    No. of Class of Conductor Thickness No. of Class of Conductor Thickness
    CoresxCross Section   CoresxCross Section  
    No.xmm²   mm mm mm No.xmm²   mm mm mm
    1x1.5 2 0.7 0.4 1.4 3x1.5 2 0.7 0.4 1.8
    1x2.5 2 0.7 0.4 1.4 3x2.5 2 0.7 0.4 1.8
    1x4.0 2 0.7 0.4 1.4 3x4.0 2 0.7 0.4 1.8
    1x6.0 2 0.7 0.4 1.4 3x6.0 2 0.7 0.4 1.8
    1x10 2 0.7 0.4 1.4 3x10 2 0.7 0.6 1.8
    1x16 2 0.7 0.4 1.4 3x16 2 0.7 0.6 1.8
    1x25 2 0.9 0.4 1.4 3x25 2 0.9 0.8 1.8
    1x35 2 0.9 0.4 1.4 3x35 2 0.9 0.8 1.8
    1x50 2 1 0.6 1.4 3x50 2 1 1 1.8
    1x70 2 1.1 0.6 1.4 3x70 2 1.1 1.2 1.9
    1x95 2 1.1 0.6 1.5 3x95 2 1.1 1.2 2
    1x120 2 1.2 0.8 1.5 3x120 2 1.2 1.2 2.1
    1x150 2 1.4 0.8 1.6 3x25 2 0.9 0.6 1.8
    1x185 2 1.6 0.8 1.6 3x35 2 0.9 0.8 1.8
    1x240 2 1.7 1 1.7 3x50 2 1 0.8 1.8
    1x300 2 1.8 1 1.8 3x70 2 1.1 1 1.9
    1x400 2 2 1.2 1.9 3x95 2 1.1 1.2 2
    1x500 2 2.2 1.2 2 3x120 2 1.2 1.2 2.1
    2x1.5 2 0.7 0.4 1.8 4x1.5 2 0.7 0.4 1.8
    2x2.5 2 0.7 0.4 1.8 4x2.5 2 0.7 0.4 1.8
    2x4.0 2 0.7 0.4 1.8 4x4.0 2 0.7 0.4 1.8
    2x6.0 2 0.7 0.4 1.8 4x6.0 2 0.7 0.6 1.8
    2x10 2 0.7 0.6 1.8 4x10 2 0.7 0.6 1.8
    2x16 2 0.7 0.6 1.8 4x16 2 0.7 0.6 1.8
    2x25 2 0.9 0.8 1.8 4x25 2 0.9 0.8 1.8
    2x35 2 0.9 0.8 1.8 4x35 2 0.9 1 1.8
    2x50 2 1 1 1.8 4x50 2 1 1 1.8
    2x70 2 1.1 1 1.8 4x70 2 1.1 1.2 2
    2x95 2 1.1 1.2 1.9 4x95 2 1.1 1.2 2.1
    2x120 2 1.2 1.2 2 4x120 2 1.2 1.2 2.3
    2x25 2 0.9 0.6 1.8 4x25 2 0.9 0.8 1.8
    2x35 2 0.9 0.6 1.8 4x35 2 0.9 0.8 1.8
    2x50 2 1 0.8 1.8 4x50 2 1 1 1.8
    2x70 2 1.1 0.8 1.8 4x70 2 1.1 1.2 2
    2x95 2 1.1 1 1.9 4x95 2 1.1 1.2 2.1
    2x120 2 1.2 1 2 4x120 2 1.2 1.2 2.3

    what is bs 8375 cable

    BS8573 is a British Standard for cross-linked polyethylene (XLPE) insulated and low smoke zero halogen (LSZH) sheathed cables. These cables are designed to increase fire safety and reduce smoke in the event of a fire. They are suitable for use in areas where fire safety and environmental impact are key considerations.

    BS8573 cables have XLPE insulation and an LSZH sheath. XLPE insulation material is excellent for electricity and heat. The LSZH sheath stops toxic and corrosive gases being released when it gets hot. This material combination is safer and has a smaller impact on the environment than traditional PVC cables.

    BS8573 cable is used in places where fire safety and less smoke are important, like public buildings, transport, and areas with strict safety rules. This cable is fire-resistant and low-smoke for use in distribution, control, and instrumentation.

    When choosing and using LSZH cable, think about what you need for the installation. This includes following the right standards, thinking about the environment and needing fire-resistant and low-smoke cables. Following industry best practices and installation guidelines will help ensure the safe use of these cables.